| PRODUCT GUIDE |
 |
 |
 |
| RV10K
Roofline Tile Roof Vents |
 |
The unique Harcon Roofline range
offers high or low roof ventilation through vents that
are almost invisible from the ground. The design of the
patented Harcon 'discreet cassette' system separates water
from the air, so the water is retained above the roofline
at all times.
The Roofline vents incorporate a factory fitted round
felt sleeve which penetrates the felt, so no extra sleeve
is required. This round sleeve significantly reduces the
felt tearing that can occur around rectangular spigots. |
 |
 |
|
 |
 |
 |
RV8K
Roofline Plain Tile Roof Vents |
 |
| The Harcon plain tile vents are
an extremely neat and compact design to match the standard
265mm x 165mm plain tile. They are installed simply, replacing
only 3 tiles, without the need to cut any roof battens
or surrounding tiles, making them ideal for all new build
and refurbishment applications. They incorporate a felt
sleeve which fits neatly between the battens. Also available
for other small tiles. |
 |
 |
|
 |
 |
 |
| RV10K Roofline
Slate Roof Vents |
 |
| Designed for easy fitting with all slate sizes,
the 600mm x 300mm avoids the need for cutting upslope
slates. All Harcon slate Roof vents are supplied with
a 110mm dia. spigot for pipe termination as standard.
This can be cut back to provide a full 10,000mm² ventilation. |
 |
 |
 |
| RP 10K Pipe
Terminals |
 |
| The Harcon COA1 adaptor can be simply clipped
on to the RV10K Roofline roof vent spigot, thus forming
the RP10K terminal for soil or extractor pipes.
The adaptor offers a 110mm dia. outlet as standard,
this can be cut down to provide a 125mm dia. section
if needed. |
 |
 |
 |
| RP8K Pipe
Terminals |
 |
| The NSA110 adaptor (not shown) can be simply site
fitted to the RV8K roofline plain tile roof vents thus
forming the RP8K terminal for soil or extractor
pipes. The adaptor offers a 110mm dia. outlet as
standard. |
|
 |
 |
|
 |
 |
 |
| CT1C Flexitube |
 |
| The Harcon flexitube is a high
quality, durable product. It connects pipe terminals to
110mm dia. soil or extractor pipes; pressure tested in
accordance with BS5250. Supplied compressed and netted
with fixing clips. |
 |
 |
|
 |
 |
 |
| RP10K / RV10K 'discreet
cassette' system |
 |
Patented discreet
cassette system showing the paths of water and air.
This system prevents the water from ever entering the
vent, instead it flows down the internal channels to
re-emerge on the tile surface and flow away down the
roof. |
 |
 |
|
 |
 |
 |
| FW1 Felt Weir |
 |
| It is always necessary to cut
and fold back the felt before fitting a roof vent. If this
is done by following the Harcon fixing instructions no
leakage will occur. However a ‘felt weir’
is available as an extra safeguard, it guides any condensation
or rain water coming down the felt away from the vent
opening. |
 |
 |
|
 |
 |