Technical DataTechnical Data |
|
|
 |
| Technical |
 |
| For greater technical detail – refer to HARCON Technical Data Sheets |
 |
| Valley Weights |
 |
|
| Standard valley troughs (HD, HA, HB) |
|
1.64kg/m² |
| Heavy weight valley troughs (DX, AX, BX) |
|
2.10kg/m ² |
| Valley Thickness |
|
|
| Standard valley troughs (HD, HA, HB) |
|
1.3mm |
| Heavy weight valley troughs (DX, AX, BX) |
|
1.6mm |
|
 |
| Valley Selection Table |
 |
| The open width of a valley in any slate or tile roof is specified in BS5534: part 1: 1997 depending on rafter pitch and roof area to be drained. To ensure compliance with this, use the following table to select the appropriate HARCON valley trough type: |
 |
|
| Rafter Pitch (degrees) |
Valley Type |
Max. Valley Length |
Valley Type |
Max. Valley Length |
Minimum Lap Length |
| 17.5 to 22 |
B / D |
7.0m |
- |
- |
350mm |
| 22.5 to 29 |
A / B / D |
7.0m |
B / D |
14.5m |
300mm |
| 30 to 34 |
A / B / D |
7.5m |
B / D |
15.0m |
200mm |
| 35 to 39 |
A / B / D |
7.5m |
B / D |
15.5m |
200mm |
| 40 to 44 |
A / B / D |
8.0m |
B / D |
16.5m |
150mm |
| 45 to 49 |
A / B / D |
8.5m |
B / D |
17.0m |
150mm |
| 50 to 55 |
B / D |
9.0m |
B / D |
18.5m |
150mm |
|
 |

|